3.8
Selecting an Operating Mode
MODE CONTROL
The KODAK MEGAPLUS Camera operates in one of four modes, continuous,
control, trigger, or retriggered. The mode of operation is selected by the mode
command.
Continuous
The camera can take pictures at 15, 25, 30, 50, 60, and 85 frames per second
(fps). The frame rate is set by the FRS command, The default frame rate is
30 fps. The exposure time range is from 94 microseconds to one divided by the
frame rate. For example, the maximum exposure is 11 milliseconds at 85 fps.
The camera can be synchronized to an external trigger source through the Trigger
input on the rear panel of the camera or the EXPOSE input of the AIA interface
connector. The trigger input frequency must be between 84.5 and 85.5 Hz. If the
camera is not externally triggered its frame rate will be 84.5 fps. When multiple
cameras are driven from the same trigger source they will be synchronized to
each other within ± 100 nanoseconds. The digital video output pauses for one
row time at the time the exposure starts for the next frame. See continuous mode
timing diagram in chapter 4 for details.
Control
The start and exposure time of each image is controlled directly by the user.
Control is accomplished by the EXPOSE input pins in the AIA interface connec-
tor or the trigger input on the rear panel of the camera. The exposure time is
equal to the time the EXPOSE input signal is true. The frame rate is inversely
proportional to the exposure plus readout time. The exposure time can be as long
as needed, but at room temperatures dark field nonuniformities become more
noticeable with increasing exposure times.
Trigger
Each exposure is started by a signal connected to the EXPOSE input pins of the
AIA interface connector or the trigger input on the rear panel of the camera. The
exposure command sets the exposure time. An exposure starts 20 microseconds
(± 100 nanoseconds) after the active edge of the trigger pulse and ends after the
exposure time set by the EXE command. The active edge of the trigger pulse is
selected using the TRM command.
The EXPOSE input sets the start time for each frame of video. The camera will
ignore additional EXPOSE signals until it completes the current exposure. The
trigger mode of operation is used to capture a single image or sequence of
images.